bool EnableAccelerationLog(bool, int, int, int, string)
This function can be used to start a new recording or stop a recording in progress while in acceleration logger mode.
Security
Trust Level Required: Full Trust
Parameters
Name | Description |
enable |
bool True to begin logging, false to stop a log in progress. |
frequency |
int The interval at which the logger will record acceleration data. |
startPage |
int The memory page index where recording will begin. |
endPage |
int The maximum page index for recording data, after which recording will automatically stop. |
devName |
(Optional) string The name of the device. If not supplied, the first matching configured device of this type will be used |
Return
True if the values were set succesfully. False otherwise.
Remarks
Examples
function enableAccelLog() {
var enable = document.getElementById('enableAccel').checked;
var freqEl = document.getElementById('frequency');
var frequency = parseInt(freqEl.options[freqEl.selectedIndex].innerHTML);
var startPage = parseInt(document.getElementById('startPage').value);
var endPage = parseInt(document.getElementById('endPage').value);
alert('Success: ' + KioOmronEnviroSensor.EnableAccelerationLog(enable, frequency, startPage, endPage));
}
Requirements
KioWare for Windows version 8.16 or greater.