bool SetInstallationOffset(OffsetType, bool, double, string)
Set a calibration offset value to automatically add or subtract from the raw sensor data.
Security
Trust Level Required: Full Trust
Parameters
Name | Description |
offsetType |
OffsetType
The calibration offset type |
enable |
bool True to enable the offset for the given type, false to disable. |
value |
(Optional) double The offset value to add or subtract from the raw sensor data. |
devName |
(Optional) string The name of the device. If not supplied, the first matching configured device of this type will be used |
Return
True in the event that the given values were set succesfully. False otherwise.
Remarks
Examples
function setInstallOffset() {
var offsetType = document.getElementById('offsetType').selectedIndex;
var enable = document.getElementById('offsetEnable').checked;
var value = parseInt(document.getElementById('offsetValue').value);
if (isNaN(value)) value = -1;
alert('Success: ' + KioOmronEnviroSensor.SetInstallationOffset(offsetType, enable, value));
}
Requirements
KioWare for Windows version 8.16 or greater.